Flexible Sensor Actuator cable UL2464 UL2517 UL20276 UL20549 UL21198

Serial Code : A0510010 Product Code : Sensor cable-UL series
DetailsTechnical dataArticle tableCertifications and standardsPacking detailsPacking details

Applications:

Versatile Machine Interface Cable for Low‑Frequency Data & Signal Transmission

Designed for universal use at machine interfaces, this cable supports reliable data and signal transmission across a wide range of low‑frequency applications.

 

Key Properties:

  • Suitable for fixed installation and occasional flexing

  • Approved for use in dry and damp environments

  • Rated for medium mechanical stress

  • PUR / PVC outer jacket resists acids, alkaline solutions, and provides limited oil resistance

  • Suitable for outdoor use within the specified temperature range

Ideal for industrial control systems, sensor networks, and equipment interfaces where durability, chemical resistance, and reliable low‑frequency communication are required in varied environmental conditions.

Conductor material

Bare Copper (according to DIN EN 60228)

Tinned Copper (according to DIN EN 60228)

Conductor design

IEC 60228 class 6

Core identification

Colors

Core insulation

PP

PVC

TPE

Core stranding

Cores wound with an optimised pitch length.

Shielded

No

Outer jacket

PVC

TPU

Outer jacket color

Black RAL9005

Grey RAL7001

Product type

Encoder cable

Installation cable

Motor connection cable

Power and control cable

Robotic cable

Application area

Flexible

Cable chain

Torsion

Nominal voltage

<0.5mm²:U0/U 300/300V

0.5mm²-4.0mm²:U0/U 300/500V

Test voltage

<0.5mm²:1500V

0.5mm²-4.0mm²:2000V

Temperature, fixed

-15°C to +70°C (according to DIN EN 50305)

-40°C to +105°C (according to DIN EN 50305)

Temperature, flexible

-5°C to +70°C (according to DIN EN 50305)

Min. bend radius, fixed

6 x OD

Min. bend radius, flexible

10 x OD

Flame retardant

According to IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2/Horizontal Flame

Halogenfree

According to VDE 0472-815

Lead-free

According to 2011/65/EU (RoHs-II/RoHS-III)

NFPA

According to NFPA 79-2018

Oil resistance

According to DIN EN 60811-2-1

PTFE-free

The design of these products does not contain PTFE

PWIS-free

According to VDMA 24364-B2-L

REACH

According to (EC) No. 1907/2006 (REACH)

Silicone-free

According to PV 3.10.7 – status 1992

UL verified

According to UL 758

UV resistance

According to UL sunlight resistant

CE marking

NO.: ICR/VC/HM2506125

UL certification

UL e-file number: E497459

cUL certification

cUL e-file number: E497459

TÜV certified

Registration NO.: AN 50618281 0001

Item no. Cable type No. of cores x cross section Insulation-ø Outer-ø ± 10% Copper figure
AY-D519 With shielded 12*0.14 mm² 1.0 mm 6.8 mm 15.14 kg/km
AY-D2767 No shielded 12*0.14 mm² 1.0 mm 6.4 mm 15.14 kg/km
AY-D266 With shielded 12*0.25 mm² 1.17 mm 7.4 mm 26.92 kg/km
AY-D2829 No shielded 12*0.25 mm² 1.17 mm 7 mm 26.92 kg/km
AY-D1381 No shielded 17*0.14 mm² 1.0 mm 8 mm 21.45 kg/km
AY-D1382 With shielded 17*0.14 mm² 1.0 mm 8 mm 21.45 kg/km
AY-B510031 No shielded 2*0.14 mm² 0.9 mm 2.8 mm 2.52 kg/km
AY-C848 With shielded 2*0.14 mm² 1.0 mm 3.6 mm 2.52 kg/km
AY-C1530 With shielded 2*0.25 mm² 1.17 mm 4.8 mm 4.49 kg/km
AY-D2076 No shielded 2*0.25 mm² 1.6 mm 5 mm 4.49 kg/km
AY-C771 No shielded 2*0.34 mm² 1.3 mm 4.8 mm 5.89 kg/km
AY-C2392 With shielded 2*0.34 mm² 1.3 mm 5.1 mm 5.89 kg/km
AY-B510035 No shielded 3*0.14 mm² 1.0 mm 3.7 mm 3.79 kg/km
AY-B510019 No shielded 3*0.25 mm² 1.17 mm 4.3 mm 6.73 kg/km
AY-B520019 With shielded 3*0.25 mm² 1.17 mm 4.7 mm 6.73 kg/km
AY-B510015 No shielded 3*0.34 mm² 1.3 mm 4.3 mm 8.83 kg/km
AY-B520015 With shielded 3*0.34 mm² 1.3 mm 5 mm 8.83 kg/km
AY-B510037 No shielded 4*0.14 mm² 1.0 mm 3.7 mm 5.05 kg/km
AY-D2172 With shielded 4*0.14 mm² 0.9 mm 4.6 mm 5.05 kg/km
AY-B510023 No shielded 4*0.25 mm² 1.17 mm 4.5 mm 8.97 kg/km
AY-B520023 With shielded 4*0.25 mm² 1.17 mm 5 mm 8.97 kg/km
AY-B510007 No shielded 4*0.34 mm² 1.3 mm 4.7 mm 11.78 kg/km
AY-B520007 With shielded 4*0.34 mm² 1.3 mm 5.3 mm 11.78 kg/km
AY-B510027 No shielded 5*0.25 mm² 1.17 mm 5 mm 11.22 kg/km
AY-B520027 With shielded 5*0.25 mm² 1.17 mm 5.4 mm 11.22 kg/km
AY-B510011 No shielded 5*0.34 mm² 1.3 mm 5.4 mm 14.72 kg/km
AY-B520011 With shielded 5*0.34 mm² 1.3 mm 6 mm 14.72 kg/km
AY-D804 No shielded 6*0.08 mm² 0.8 mm 4.5 mm 4.31 kg/km
AY-D1911 No shielded 6*0.08 mm² 0.8 mm 4.4 mm 4.21 kg/km
AY-C470 With shielded 6*0.14 mm² 1.0 mm 5 mm 7.57 kg/km
AY-C855 No shielded 6*0.14 mm² 1.0 mm 5 mm 7.57 kg/km
AY-C1643 No shielded 6*0.25 mm² 1.17 mm 5.4 mm 13.46 kg/km
AY-C1703 With shielded 6*0.25 mm² 1.17 mm 6.1 mm 13.46 kg/km
AY-D411 No shielded 6*0.34 mm² 1.3 mm 6.2 mm 17.67 kg/km
AY-C1610 No shielded 7*0.25 mm² 1.17 mm 5.8 mm 15.7 kg/km
AY-C2856 No shielded 8*0.14 mm² 1.0 mm 5 mm 10.09 kg/km
AY-D2708 With shielded 8*0.14 mm² 1.0 mm 6 mm 10.09 kg/km
AY-C852 With shielded 8*0.2 mm² 1.1.0 mm 6 mm 14.58 kg/km
AY-C933 No shielded 8*0.2 mm² 1.1.0 mm 5.8 mm 14.58 kg/km
AY-B510004 No shielded 8*0.25 mm² 1.17 mm 6 mm 17.95 kg/km
AY-B520004 With shielded 8*0.25 mm² 1.17 mm 6.5 mm 17.95 kg/km
AY-D2982 No shielded 8*0.34 mm² 1.3 mm 6.6 mm 23.55 kg/km
UL NO. Rating Shield Jacket
2464 80 deg C, 300 Vac, Cable flame. Optional Extruded PVC
2517 105 deg C, 300 Vac, Cable Flame. Optional Extruded PVC
20276 60 or 80 deg C, 30 V ac, Cable Flame on construction A, Horizontal flame on construction B. Optional Extruded PVC
20549 80 deg C, 300 Vac, Horizontal flame. Optional Extruded TPU
21198  80 deg C, 300 Vac, Horizontal flame. Optional Extruded TPU

Laboratories and Test Centers

In our laboratories, we evaluate the long‑term effects of environmental factors — including UV exposure, rain, ozone, seawater, oils, and cleaning agents — on the materials used in our products.

Within our dedicated test facilities, we conduct rigorous performance assessments such as:

  • Electrical transmission and signal integrity verification
  • Service life and endurance testing
  • Continuous load validation under demanding conditions
  • Fire behavior and flame‑resistance analysis

These comprehensive tests directly inform the design and manufacturing of future Anyang® products.  Our multi‑stage validation processes ensure not only compliance with industry standards and legal requirements, but also support our commitment to sustainability and environmental regulations — including REACH and RoHS — through verified material safety and product reliability.

 

Validated Through Rigorous Testing

Not all tests deliver the same level of assurance.  Only the most demanding evaluations can verify true performance under real‑world conditions.  That is why every product and material undergoes stringent validation in our specialized testing centers.

We assess practicability, durability, and compatibility across diverse application environments—ensuring that each solution meets the precise needs of our customers.  Upholding this commitment is a responsibility we take seriously: to deliver on our promise of consistent, reliable, and high‑quality connectivity.

  • RoHs 2.0

    RoHs 2.0

  • Reach

    Reach

  • ISO 9001

    ISO 9001

  • UL

    UL

  • TÜV

    TÜV

  • VDE

    VDE

Testing video

Speed, Reliability, and Flexibility: The Pillars of Anyang Logistics

In today’s global market, logistics demands speed, reliability, and flexibility—standards that Anyang meets through a state-of-the-art, fully integrated network of logistics and service centers.

Beyond fast and dependable cable shipment, we provide a comprehensive suite of logistics products and services designed to streamline your operations.  Our portfolio includes tailored transport, storage, and unwinding solutions that enable efficient cable handling and integration into your workflow.

These capabilities not only enhance supply chain performance but also drive tangible process efficiencies—helping you stay agile and competitive in a rapidly evolving marketplace.

Packing details

Wooden Roll
Wooden Roll

Roll
Roll

Shipping Package
Shipping Package